Parker P2LDX514EENXB549
Parker Viking Xtreme — P2LDX (G1/2)
Parker P2LDX514EENXB549 — Viking 5/2-way directional control valve: G1/2 ports, double solenoid, 24 V DC, 15 mm solenoid, internal pilot supply, 10 bar maximum. The Janatics DS257SS63-W shown here matches it on valve function, port size, coil voltage and maximum working pressure. Two differences worth knowing. Temperature: this valve is rated +5 °C to +60 °C, where the Parker part is rated -10 °C to +50 °C, so it is not a like-for-like choice below +5 °C, and its minimum working pressure is 2 bar against a 1.5 bar minimum signal pressure for the Parker. Supply: the Parker part number covers the valve and solenoid only, with the plug ordered separately and built to the 15 mm Form C / ISO 15217 pattern, whereas this valve is supplied complete with 22 mm coils and PG9 connectors. If you are reusing existing wired plugs, check the connector form before ordering.